Plasma source mass espectroscopy
| Support unit | Support unit Information | Selected service | Other services |
|---|---|---|---|
|
IACT-CSIC - Armilla |
Service general data
- Support unit: ANDALCHRON
- Institute: INSTITUTO ANDALUZ DE CIENCIAS DE LA TIERRA IACT-CSIC
- Locality: Armilla (Granada)
- Service's web: http://www.andalchron.eu
El servicio científico-técnico (SCT) de Andalchron, parte de los laboratorios multi-escala de la infraestructura europea ESFRI-EPOS, oferta prestación de servicios en espectrometría de masas con fuente de plasma para la determinación de razones isotópicas mediante espectrometría de masas con fuente de plasma (ICP-MS) para su uso en geocronología. Esta prestación ofrece análisis mediante ICP-MS con analizador de masas cuadrupolar (ICP-QMS) y de sector magnético de alta resolución y con detección multicanal (MC-ICP-MS), de disoluciones, y de sólidos mediante ablación láser (LA-ICP-MS y LA-MC-ICP-MS). El servicio oferta prestaciones de servicios auxiliares en microscopía y espectroscopia, preparación de muestras y sala blanca dirigidas única y exclusivamente a la caracterización y/ preparación de muestras asociadas a las prestaciones de servicios en espectrometría de masas. Los usuarios deben de ponerse en contacto con el servicio para estudiar las solicitud de prestación solicitada.
Plasma source mass espectroscopy
Benefit description
The Andalchron service unit offers plasma source mass spectrometry services for the determination of isotope ratios by mass spectrometry with quadrupole mass analyzer (ICP-QMS; ICP-MS/MS) and high-resolution magnetic sector with multichannel detection (MC-ICP-MS), in solutions and, by laser ablation, of solids (LA-ICP-MS and LA-MC-ICP-MS). For internal use of the equipment (CSIC), this service is only offered in self-service mode (use by user) depending on the availability based on the external demand of the service, not being effective the variants of sample preparation by technician and data processing. Self-service may only be performed by trained users with prior authorization by the technical manager of the service.| Options | Unit | Public Sector | Other customers |
|---|---|---|---|
| ICP-QMS espectrómetro cuadrupolo con fuente de plasma | € / hora | 98.26 € | 170.07 € |
| MC-ICP-MS Neptune XT | € / hora | 196.89 € | 330.91 € |
| Determinación de razón isotópica de Sr y Nd | € / muestra | 199.51 € | 408.1 € |
| Determinación razon isotópica de Nd | € / muestra | 149.27 € | 305.32 € |
| Determinación de razón isotópica de Sr (muestra rica en Rb) | € / muestra | 119.28 € | 280.06 € |
| Determinación de razón isotópica de Sr (muestra pobre en Rb) | € / muestra | 102.03 € | 242.94 € |
| ICP-MS medida ultralímpia de alta precisión | € / muestra | 31.84 € | 52.19 € |
| Preparación especial muestra por técnico | € / hora | 57.35 € | 98.62 € |
| Ablación láser de 193nm | € / hora | 46.99 € | 83.14 € |
| Procesado de datos | € / hora | 54.14 € | 93.71 € |